Parameter Suggested Method of Analysis Description of Method Suggested Frequency Use of data
Carbonate EPRI Method N1 CO2 evolution, Ba(OH)2 absorption, Acid-base titration Start and finish of each performance test run. Measuere alkali loss in filter cake of mag-lime process; important for mag-lime or sodium systems.
Alkalinity EPRI Method N3 Titrimetric Start and finish of each performance test run. Measuere alkali loss in filter cake of mag-lime process; important for mag-lime or sodium systems.
Calcium and Magnesium EPRI Method J1 EDTA Titration Start and finish of each performance test run. Check for reagent quality
Inerts EPRI Method J1 Acid Dissolution Start and finish of each performance test run. Quality indicator. Important for gypsum systems.
Limestone slurry solids content EPRI Method F1 Gravimetric Start and finish of each performance test run. Check density meter and indicate problems in milling circuit
Lime slurry particle size distribution EPRI Method G1 Wet Sieve Start and finish of each performance test run. Troubleshooting problems in milling circuit or process such as low utilization or poor gypsum quality